Numerical investigation of the transient behavior of the recuperative heat exchanger in a MRJT cryocooler with different condensation correlations

Guide

Date of Issue

Sep.2016

Type

Article

Guide

Subject Keywords

Barcode

Class number

Abstract

In J-T cryocoolers operating with mixed refrigerants (nitrogen-hydrocarbons), the recuperative heat exchange takes place under two-phase conditions. Simultaneous boiling of the low pressure stream and condensation of the high pressure stream results in higher heat transfer coefficients. The mixture composition, operating conditions and the heat exchanger design are crucial for obtaining the required cryogenic temperature. In this work, a one-dimensional transient algorithm is developed for the simulation of the two-phase heat transfer in the recuperative heat exchanger of a mixed refrigerant J-T cryocooler. Modified correlation is used for flow boiling of the high pressure fluid while different condensation correlations are employed with and without the correction for the low pressure fluid. Simulations are carried out for different mixture compositions and numerical predictions are compared with the experimental data. The overall heat transfer is predicted reasonably well and the qualitative trends of the temperature profiles are also captured by the developed numerical model

Identifier URL

Pages

52-62p.

Faculty

Faculty of Technology

Citation

Source URL

Keywords

J-T cryocooler Transient Mixed-refrigerant Heat-exchanger

DOI

10.1016/J.CRYOGENICS.2016.09.003

ISBN

Place of Publication

Publication Year

Edition

Provider

ISSN Number

Volume Number

Issue Number

Journal Name

Publication

Elsevier

Class Number

Collections